• Twitter
  • Facebook
  • LinkedIn
  • Youtube
  • Xing
  • Deutsch Deutsch German de
  • English English English en
Phone +49 7144 89718-0 | info@schildknecht.ag
  • 0Shopping Cart
Schildknecht AG - Radio Data Technology
  • Home
  • Products
    • Industrial Wireless
      • Wireless Ethernet
      • Wireless Safety
      • Wireless PROFIBUS
      • Wireless CAN
      • Wireless PLC / IO
      • Antennas and Accessories
    • IoT and M2M
      • IoT and M2M solution
      • IoT Ready-to-use
        • Condition Monitoring
        • Energy Monitoring
      • IoT Gateways
      • DATAEAGLE Portal – Device Cloud
    • Antennas and Accessories
      • Antenna Products
      • Antenna basics
      • Antenna installation
      • antenna mounting guidelines
      • Use Case
    • Wireless Sensor Network
      • Make Your Sensor Wireless
      • Wireless Sensor PLC
      • Wireless Sensor Cloud
      • DATAEAGLE Beacon
      • Bluetooth Sensors
    • Product Overview
    • Services
  • Blog
  • Case Studies
    • Industry Sectors
      • Crane & Hoist Technology
        • Galvanizing Plant
        • Condition Monitoring E-RTG-Cranes
        • Remote Monitoring of Cranes and Hoists
      • Radio data transmission in stage technology
        • Wireless stage technology at Helene Fischer
      • Radio data systems for intralogistics
        • AGVs with radio links
        • Cable Substitute in the Cold Running Mill
      • Smart Farming
      • Water management
        • Radio data transmission in wastewater treatment plants
        • Water level measurement via Twitter
      • Industrial Wireless Technology in Process Industry
        • Industrial Wireless Technology in Stranding Machines
        • Cable Substitute in the Cold Running Mill
      • Industry 4.0 practical examples
        • Condition Monitoring of Motors
        • Remote Monitoring of Cranes and Hoists
        • Food and Beverage: Remote Access to Machines
        • Condition Monitoring E-RTG-Cranes
      • Internet of Things Examples
        • Remote Monitoring of motorway facilities
    • IIoT Scenarios
    • Case Studies
  • Download
    • Product information
    • Whitepaper – Comparsion of data transmission technologies
    • Whitepaper – Wireless Quick Check
    • Whitepaper – Antenna 101
  • Webinars
  • About Us
    • About us
    • News and Videos
    • Radio Wikipedia
  • Contact
    • Contact
    • Project Request Industrial Wireless
    • Repair & Support
    • Services
    • Team
    • Distributor
  • Search
  • Menu

Industrial Wireless

Industrial Wireless

  • Sort by Default
    • Default
    • Custom
    • Name
    • Price
    • Date
    • Popularity (sales)
    • Average rating
    • Relevance
    • Random
    • Product ID
  • Display 15 Products per page
    • 15 Products per page
    • 30 Products per page
    • 45 Products per page
  • Wireless PLC / IO - DATAEAGLE Compact 2710

    DATAEAGLE 2000 Compact

  • Wireless PLC / IO - DATAEAGLE Compact 2710

    DATAEAGLE Compact 2330 / 2340

  • DATAEAGLE 2730 Compact • Über Bluetooth Low Energy vom Sensor in die Steuerung

    DATAEAGLE Compact 2730

Page 6 of 7«‹4567›

FAQ

What does Black Channel mean?

What does Black Channel mean?

The black channel principle allows the transmission of safe and non-safe process data over the same network or bus line. Regardless of the regular data transport mechanism used on this line, safety components can transmit data using an isolated safe protocol that tunnels through the underlying network channel. Since safe fieldbuses are pure application protocols without their own physical properties, the available bandwidths and cycle times depend on the data transport protocol used. Possible transmission errors are known and are listed in the relevant standards IEC 61784-3 and IEC 61508.

Black Channel explained in detail!

What does this mean for PROFIsafe?

The PROFIsafe protocol has no repercussions on the standard bus protocols. It is intended to be as independent as possible of the respective transmission channel, whether copper cable, fiber optic cable, backplane bus, or wireless. Neither the transmission rates nor the respective error detection plays a role. For PROFIsafe, the transmission channels are merely “black channels”.

 

Wireless PROFIsafe - Black Channel Principle

Wireless PROFIsafe – Black Channel Principle

 

PROFIsafe – same protocol for radio and cable

Whether for a crane control system, the emergency stop transmission of a production machine, or other safety-relevant communication: PROFIsafe has been established as a standard for functionally safe communication and has been an international standard since 2007 under the designation IEC 61784-3-3. The safety-related protocol is used to transmit data between a safety controller (F-PLC or F-Host) and field devices (F-Devices). While the controller and device are usually safety-related components and must be certified accordingly, PROFIsafe, according to the system description, has no effect on the standard bus protocols used: whether with Industrial Ethernet (PROFINET IO), via RS485 (PROFIBUS-DP), via backplanes or wireless – the method used for data transmission has no influence on the safety rating. The transmission channels are merely so-called “black channels”, of which the actual PROFIsafe application is completely independent. Accordingly, the PROFIsafe system description also states: Wireless transmission is permissible as long as sufficient availability (no false alarms) and IT security are guaranteed.

 

Secure data transmission by radio: the black channel principle in detail

This means that the use of wireless technologies is also provided for and possible by definition, just like other radio technologies. Both the safety controller and the remote IO system – for example a safety switch – contain the safety protocol. The interface between them is merely the channel for transmitting the safety information. Accordingly, no safety certification is required for the wireless device and it is treated like other infrastructure components, such as switches or cables. This makes the recalculation or verification of the safety level (SISTEMA) for using a black channel solution obsolete.

 

More Informations:

Wireless PROFIsafe – Our Radio Data Systems

Read our Blog Article

Is PROFIsafe via radio permitted?

The black channel principle allows the transmission of safe and non-safe process data over the same network or bus line. Independent of the regular data transport mechanism used on this line, safety components can transmit data using an isolated safe protocol that tunnels through the underlying network channel. Since safe fieldbuses are pure application protocols without their own physical properties, the available bandwidths and cycle times depend on the data transport protocol used. Possible transmission errors are known and listed in the relevant standards IEC 61784-3 and IEC 61508.

What does this mean for PROFIsafe?

The PROFIsafe protocol has no repercussions on the standard bus protocols. It is intended to be as independent as possible of the respective transmission channel, whether copper cable, fibre optic cable, backplane bus or wireless. Neither the transmission rates nor the respective error detection play a role.

For PROFIsafe, the transmission channels are merely “black channels”. The DATAEAGLE 3732 and DATAEAGLE 4732 wireless PROFISAFE data radio systems were specially developed for the wireless transmission of PROFIsafe via Bluetooth. The use of the patented filter technology guarantees a stable, reliable radio connection, without bus errors in your PROFIsafe applications.

– Wireless PROFIsafe

 

Schildknecht
Schildknecht AG
Haugweg 26
71711 Murr

+49 7144 89718-0
info@schildknecht.ag

www.schildknecht.ag

Service Links

  • Services
  • Privacy Policy
  • Impressum
  • General Terms of Business
  • Disclaimer

Cookie-Settings

NEWSLETTER

Social

  • Twitter
  • Facebook
  • LinkedIn
  • Youtube
  • Xing
© Copyright - Schildknecht AG - made by fernsicht.media

WordPress Download Manager - Best Download Management Plugin

Scroll to top